BS MXV-BE
FLOW
2/39
mc / h
HEAD
12.7 / 126.5
m
POWER
1.35 / 1.8 x3
kW
,
,
Execution
Vertical multi-stage stainless steel pumps with integrated VFD.
MXV-BEM: AISI 304 version.
MXV-BELM: AISI 316 version.
Complete with an integrated pressure transducer that maintains constant
system pressure even during the opening and closing of user outlets.
2 and 3-pump booster sets
Suction and delivery manifolds in stainless steel AISI 304.
Connections for the installation of one G 1″ connection pressure vessel
Applications
For water supply systems.
For clean liquids, without abrasives, which are non-aggressive for stainless steel
(with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial applications, for garden
use and irrigation.
Operating conditions
Liquid temperature from 0 °C to +40 °C.
Ambient temperature up to 40° C.
Maximum permissible pressure in pump casing: 16 bar.
Continuous duty.
Motor
2-pole induction motor.
Rated speed 5400 rpm
Motor: variable speed
Frequency: 50-60 Hz
Single-phase 220-240V~50Hz/60Hz
H07RN8-F cable, 3G1.5 mm2, length 1.5 m, with CEI-UNEL 47166 plug.
Insulation class F.
Protection IP X5.
– Constructed in accordance with EN 60034-1, EN 60335-1, EN 60335-2-41.
Case History
Case History
Related products
BS METAVariable speed pressure boosting system with integrated control FLOW2 / 16,8mc / hHEAD15 / 55mPOWER1.35kW |
BS MPSUFixed and variable speed pump units FLOW1 / 24mc / hHEAD10 / 63vvvvvvvvvvvvmPOWER0.5 / 1.5x3kW |
|
BS MXVFixed and variable speed pump units FLOW1.5 / 350mc / hHEAD10 / 130mPOWER0.75 / 22x3kW |
BS MXVBFixed and variable speed pump units FLOW1.5 / 48mc / hHEAD10 / 130mPOWER0.75 / 5.5x3kW |
BS NM,NMDFixed and variable speed pump units FLOW1.5 / 570mc / hHEAD10 / 95mPOWER0.45 / 55x3kW |
EJ_DJUNI-EN 12845 units for feeding fire-extinguishing systems FLOW15 / 700mc / hHEAD20 / 90mPOWER3 /100x2kW |
MÈTAVariable speed pressure boosting system with integrated control FLOW2 / 14mc / hHEAD11 / 55mPOWER1kW |